Resistencia a fuerzas de cizallamiento en sistemas cerámicos compuestos por feldespato sobre tres tipos de tratamiento del metal: estudio in vitro
Date
2023-05-25Author
Share
Metadata
Show full item recordCollections
- Pregrado Odontología [428]
Abstract
Introducción: En odontología, la resistencia a la fuerza de cizallamiento es una propiedad importante para evaluar la estabilidad de las restauraciones dentales. Los sistemas cerámicos compuestos por feldespato son ampliamente utilizados en la odontología restauradora debido a su estética y resistencia a la fractura, sin embargo, su rendimiento depende en gran medida de la calidad del sustrato metálico. Objetivo: Evaluar la influencia que tienen los diferentes tratamientos de superficies que recibe la infraestructura metálica sobre la carga de la cerámica feldespática al ser sometida a fuerzas de cizallamiento. Método: Se confeccionaron 21 cofias metálicas de níquel cromo sobre un modelo patrón del diente 26 elaborado en yeso tipo IV. Se sometieron a tres diferentes tratamientos de superficie (oxidación, arenado y pulido). Posteriormente, se recubrieron con cerámica feldespática con un espesor de 1,5 mm y se verifico visualmente la calidad de la superficie. Se llevaron a la maquina japonesa de ensayos universales presente en la sede de la universidad Santo Tomás, marca Shimadzu autograph ag-1, la cual arrojaba los parámetros de Newtons, Segundos y Milimetros para obtener los valores de ciclo, carga y recorrido, se midieron las deformaciones producidas por la aplicación de una fuerza constante usando una velocidad con una platina de sección. Se verificaron los tipos de fallas de manera visual utilizando una lupa estereoscópica lupa La información recolectada se registró en una base de datos y se analizó estadísticamente. Se evaluó normalidad (Shapiro-Wilk), seguido de Anova One-way y post test de Sidak, establenciendo nivel de significancia <0,05% Resultados: Entre los tratamientos de superficie de las cofias metálicas al cual fue adherido la cerámica feldespática, que presento mayor diferencia significativa al resistir las fuerzas de cizallamiento se tiene, el tratamiento de arenado con un promedio de 0.731 , comparado con el tratamiento de pulido el cual presento un promedio de 0,374, observándose que entre estos dos el que presento menor resistencia a carga fue el tratamiento de pulido, Para el cruce entre Carga y Tipo de tratamiento se obtuvo como resultado un valor de p = 0.03 lo que representa una diferencia estadísticamente significativa. En la variable de stroke el grupo de arenado arrojo un valor de (1,61) teniendo este una diferencia significativa sobre los grupos de oxidado y pulido todas las coronas del grupo pulido presentaron un falla adhesiva y cohesiva. Conclusiones: El grupo de tratamiento de pulido tuvo menor valor de carga, con respecto al tratamiento de arenado y oxidado. Adicionalmente la totalidad del grupo pulido presento fracasos por fallas adhesivas-cohesivas lo cual podría tener repercusiones clínicas como la delaminación en las coronas. Entre los beneficios que podemos concluir para este estudio se encuentra relacionado la importancia del comportamiento de este sistema cerámico ante las fuerzas de cizallamiento, teniendo en cuenta el tipo de tratamiento de superficie y la pureza del metal al ser recubierta con la cerámica.
Abstract
Introduction: In dentistry, shear strength resistance is an important property to evaluate the stability of dental restorations. Feldspar composite ceramic systems are widely used in restorative dentistry due to their esthetics and fracture resistance, however, their performance is highly dependent on the quality of the metal substrate. Objective: To evaluate the influence of the different surface treatments that the metal substrates receive on the loading of feldspar ceramics when subjected to shear forces. Methods: Twenty-one nickel chromium metal copings were fabricated on a standard model of tooth 26 made of type IV gypsum. They were subjected to three different surface treatments (oxidation, sandblasting and polishing). Subsequently, they were coated with feldspathic ceramic with a thickness of 1.5 mm and the surface quality was visually verified. They were taken to the Japanese universal testing machine present at the Santo Tomas University headquarters, brand Shimadzu%EF%83%92 autograph ag-1, which yielded the parameters of Newtons, Seconds and Millimeters to obtain the values of cycle, load and stroke, the deformations produced by the application of a constant force were measured using a speed with a section plate. The information collected was recorded in a data base and analyzed statistically. Normality was evaluated (Shapiro-Wilk), followed by One-way Anova and Sidak's posttest, establishing a significance level <0.05% Results: Among the surface treatments of the metallic copings to which the feldspathic ceramic was adhered, which presented the greatest significant difference in resisting shear forces, the sandblasting treatment had an average of 0.731, compared to the sandblasting treatment with an average of 0.731, compared to the sandblasting treatment with an average of 0.05%. 731, compared to the polishing treatment which presented an average of 0.374, observing that between these two, the one that presented less resistance to load was the polishing treatment. For the cross between load and type of treatment, a value of p = 0.03 was obtained as a result, which represents a statistically significant difference. In the stroke variable the sandblasting group yielded a value of (1.61) having this a significant difference over the oxidized and polished groups all crowns in the polished group presented adhesive and cohesive failure. Conclusions: The polishing treatment group had lower load value, with respect to the sandblasting and oxidized treatment. Additionally, the entire polishing group presented failures due to adhesive-cohesive failure, which could have clinical repercussions such as delamination of the crowns. Among the benefits that we can conclude for this study is related to the importance of the behavior of this ceramic system to the shearing forces, tenacity, and strength of the ceramic system, which could have clinical repercussions such as delamination of the crowns. Among the benefits that we can conclude for this study is related to the importance of the behavior of this ceramic system under shear forces, considering the type of surface treatment and the purity of the metal to be coated with the ceramic.
PDF Documents
Estadísticas Google Analytics
xmlui.custom.comments.form-panel-heading
Respuesta Comentario Repositorio Institucional
Gracias por tomarse el tiempo para darnos su opinión.
The following license files are associated with this item: