Serpa, María FernandaGutiérrez Barreto, Javier FernandoJiménez, Oscar MauricioMonguí Fonseca, AristóbuloSalazar Múñoz, Sonia YadiraPadilla López, Julio2019-11-252019-11-252018Monguí Fonseca, A. Salazar Múñoz, S. Yadira Padilla López, J. (2018). Análisis de las alteraciones estructurales y superficiales de las limas del sistema reciproc blue® en dientes con curvaturas leves a moderadas (segunda fase). [Trabajo de Especialización]. Universidad Santo Tomás, Bucaramanga, Colombia.http://hdl.handle.net/11634/19995Objetivo: Determinar los cambios superficiales y estructurales de las limas Reciproc Blue® R25 (VDW, Munich, Alemania), después de la instrumentación y esterilización de 84 conductos con curvaturas leve a moderadas mediante microscopía de barrido y microdifracción de rayos x. Método: Se analizaron 15 limas Reciproc Blue® que se dividieron en Grupo control: una lima R25 nueva y Grupo 1: 14 limas R25 usadas en 9 y 12 conductos. Un operador experimentado instrumentó 84 conductos radiculares con curvaturas moderadas en dientes humanos extraídos con un motor electrónico X-Smart IQ. Se realizó el proceso de desinfección y esterilización y se realizó microscopía electrónica de barrido a 200X, 400X a los 9 y 12 usos. La microdifracción de rayos x se realizó en la lima nueva y en el décimo segundo uso. Resultados: La microscopía evidenció mayores irregularidades en la hoja de corte al décimo segundo uso. La microdifracción de rayos X mostró que aumentó la martensita a medida con el número de usos clínicos. Conclusión: En la primera fase del estudio se concluyó que se presentaron alteraciones mínimas en la estructura de las limas derivados de las fuerzas de tensión y compresión dentro del conducto al sexto uso. En la segunda fase del estudio se pudo concluir que las alteraciones encontradas fueron mayores debido al número superior de usos.Objective: To determine superficial and structural changes of the file Reciproc Blue® R25 files (VDW, Munich, Germany), after negotiation and sterilization of the 84 root canals with curvatures from mild to moderate using (x-ray microdifractometry and scanning electron microscopy) Method: 15 reciproc blue instrument were assessed; they were divided into control group: one R25 new and Group 1: fourteen R25 used in 9 and 12 root canals. One experienced operator performed the negotiation using an endodontic electronic motor device (X Smart IQ) in 84 human extracted teeth with moderate root canal curvatures. Disinfection and sterilization processes were done and SEM to 200X y 400X was performed to the 9 and 12 uses. Results: Major irregularities on the blade edge were evident on the microscopy assess at the 10th second of use SEM showed a boost of martensite while the number of clinical uses increased. Conclusion: At the initial stage of the study was concluded that there were minimal structural modifications in the instruments derived to tensional and compression forces within the root canal at the 6th use. At the second stage of the study was concluded that the alterations found were grater due to major number of uses.application/pdfspaAtribución-NoComercial-SinDerivadas 2.5 Colombiahttp://creativecommons.org/licenses/by-nc-nd/2.5/co/Análisis de las alteraciones estructurales y superficiales de las limas del sistema reciproc blue® en dientes con curvaturas leves a moderadas (segunda fase)bachelor thesisMicro DRXScanning electron microscopyX-ray diffractionNickel titanium instrumentsRoot canal preparationPulpa dentalCanal radicularEndodonciaRaíces dentalesInstrumentos odontológicosAbierto (Texto Completo)info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Micro DRXMicroscopía electrónica de barridoDifracción de rayos XInstrumentos de níquel titanioPreparación del conducto radicularreponame:Repositorio Institucional Universidad Santo Tomásinstname:Universidad Santo Tomásrepourl:https://repository.usta.edu.co