Pinilla Martínez, Sandra MilenaBueno Cancino, Carlos AndrésHernández Duarte, Kelly AlexandraMoreno Clavijo, Liz KatherineSagra Escalante, Silvana2019-05-022019-05-022019Bueno Cancino, C., A., Hernández Duarte, K., A., Moreno Clavijo, L., K., Sagra Escalante, S., 2019). Estudio comparativo in vitro de la resistencia adhesiva al cizallamiento de zirconia cementada a dentina con tres tratamientos de superficie. [Trabajo de Especialización]. Universidad Santo Tomás Bucaramanga, Colombia.http://hdl.handle.net/11634/16391Introducción: El uso de zirconia (3Y-TZP) maquinada se ha convertido en una opción ideal actualmente, ya que propiedades mecánicas son muy elevadas, en estas restauraciones su cementación es de forma mecánico-retentiva con cementos de sellado no adhesivos o de baja adhesión. Objetivo: Evaluar in vitro la resistencia adhesiva al cizallamiento de zirconia, cementada con un cemento resinoso autograbador, a dentina con tres tratamientos de superficie. Materiales y métodos: 60 dientes premolares seccionados en su tercio medio coronal, 60 bloques de zirconio monolítico, divididos en tres grupos de tipo experimental, agrupando 20, Grupo 1: 20 muestras cementadas con relyxU200 (3M) y tratamiento superficie previo mediante arenado con óxido de aluminio 110 μm. Grupo 2: 20 muestras cementadas con relyxU200 (3M) y tratamiento triboquímico previo con Rocatec (3M). Grupo 3: 20 muestras cementadas con relyxU200 (3M) y tratamiento superficie previo con agente primer MDP Z-PRIME Plus (BISCO). Al sustrato dental se le realizo grabado acido selectivo en esmalte con ácido fosfórico scotchbond 3M ESPE, se lavaron con agua y secaron suavemente con toallas absorbentes. Se realizó la cementación de las estructuras de zirconia con cemento autoadhesivo de polimerización dual Relyx U200 (3M). Se aplicó una presión de asiento vertical uniforme de 49 Newtons con un dispositivo de carga constante durante 6 minutos para estandarizar la cementación La fuerza de adhesión de los grupos de muestras se midió mediante el uso de una máquina de carga universal 94100 Unitek FIE, mediante la aplicación de una carga en cizalla en la interfaz Zirconio/Diente. La carga se aplicó a una velocidad constante de 0.5 mm/min hasta que se produjo una fractura. Resultados: El mayor valor de resistencia a la cizalla registrado entre todos los grupos corresponde a grupo Z-Prime con 1563,6 N y 27.6 MPa y el valor mínimo al grupo arenado con 128.5 N (2.6 MPa). El valor promedio más alto se presentó en el grupo Z-Prime con 889.9 N (15.9 MPa). Conclusiones: Los tratamientos de superficie Z-Prime plus y Rocatec evidenciaron un aumento en la resistencia adhesiva del zirconio cementado con relyx u200 en comparación con el grupo Arenado con óxido de aluminio arrojando valores promedio de 15.9Mpa, 8.9Mpa y 8.5Mpa respectivamente.Introduction: The use of machined zirconia (3Y-TZP) has become an ideal option at present, since mechanical properties are very high, in these restorations its cementation is mechanically-retentive with non-adhesive or low adhesion sealing cements . Objective: To evaluate, in vitro, the adhesive resistance to zirconia shearing, cemented with a self-etching resinous cement, to dentin with three surface treatments. Materials and methods: 60 premolar teeth sectioned in its middle third coronal, 60 blocks of monolithic zirconium, divided into three groups of experimental type, grouping 20, Group 1: 20 samples cemented with relyxU200 (3M) and previous surface treatment by sandblasting with oxide of aluminum 110 μm. Group 2: 20 samples cemented with relyxU200 (3M) and previous tribochemical treatment with Rocatec (3M). Group 3: 20 cemented samples with relyxU200 (3M) and previous surface treatment with first agent MDP Z-PRIME Plus (BISCO). The dental substrate was etched with enamel with scotchbond 3M ESPE phosphoric acid, washed with water and dried gently with absorbent towels. Cementation of the zirconia structures with Relyx U200 (3M) dual polymerized self-adhesive cement was performed. A uniform vertical seat pressure of 49 Newtons was applied with a constant load device for 6 minutes to standardize the cementation The strength of adhesion of the groups of samples was measured by the use of a universal load machine 94100 Unitek FIE, by applying a load in shear at the Zirconium / Tooth interface. The load was applied at a constant speed of 0.5 mm / min until a fracture occurred. Results: The highest value of shear resistance recorded among all the groups corresponds to the Z-Prime group with 1563.6 N and 27.6 MPa and the minimum value to the sandblasted group with 128.5 N (2.6 MPa). The highest average value was presented in the Z-Prime group with 889.9 N (15.9 MPa). Conclusions: Z-Prime plus and Rocatec surface treatments showed an increase in the adhesive strength of cemented zirconium with relyx u200 compared to the group Sandblasted with aluminum oxide, yielding average values ​​of 15.9Mpa, 8.9Mpa and 8.5Mpa respectively.application/pdfspaAtribución-NoComercial-SinDerivadas 2.5 Colombiahttp://creativecommons.org/licenses/by-nc-nd/2.5/co/Estudio comparativo in vitro de la resistencia adhesiva al cizallamiento de zirconia cementada a dentina con tres tratamientos de superficiebachelor thesiszirconiumAccessionTribochemicalMateriales dentalesCemento dentalDientesAbierto (Texto Completo)info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2ZirconioAdhesiónTriboquímicoreponame:Repositorio Institucional Universidad Santo Tomásinstname:Universidad Santo Tomásrepourl:https://repository.usta.edu.co