Comparación de dos marcas comerciales de postes de fibra de vidrio realizados sobre premolares examinando la resistencia mecánica a la fractura

Cargando...
Miniatura

Enlace al recurso

DOI

ORCID

Google Scholar

Cvlac

gruplac

Descripción Dominio:

Título de la revista

ISSN de la revista

Título del volumen

Editor

Universidad Santo Tomás

Compartir

Documentos PDF

Descripción

Este estudio tuvo como objetivo evaluar y comparar la resistencia mecánica a la fractura de dos marcas de postes de fibra de vidrio utilizadas en la clínica odontológica de la Universidad Santo Tomás, sede Floridablanca. Los postes de fibra de vidrio son elementos ampliamente empleados en la rehabilitación de dientes tratados endodónticamente, debido a que proporcionan soporte, estabilidad y una adecuada distribución de las fuerzas masticatorias, contribuyendo a la preservación de la estructura dental remanente. Para el desarrollo de la investigación se realizó un ensayo clínico in vitro utilizando una muestra de 60 primeros premolares superiores obtenidos del banco de dientes de la universidad. Los especímenes se dividieron en tres grupos: 20 dientes rehabilitados con la primera marca de poste de fibra de vidrio, 20 con la segunda marca y 20 dientes correspondientes al grupo control. A todos los dientes se les efectuó tratamiento endodóntico y posteriormente la rehabilitación correspondiente. Después, fueron sometidos a pruebas de compresión vertical con el fin de determinar su resistencia a la fractura y comparar el comportamiento mecánico entre los diferentes grupos. Los resultados mostraron el desempeño de los postes de fibra de vidrio frente a cargas compresivas verticales. Sin embargo, el análisis estadístico evidenció que ninguno de los efectos observados fue estadísticamente significativo. Esto indica que no existe evidencia suficiente para afirmar que alguna de las dos marcas evaluadas influya de manera significativa en la resistencia a la fractura o en la carga máxima soportada por los dientes en comparación con el grupo control. En conclusión, ambas marcas de postes de fibra de vidrio presentaron un comportamiento mecánico similar bajo las condiciones evaluadas. Por lo tanto, la selección de una marca específica no debería basarse únicamente en la resistencia mecánica, sino también en factores clínicos como las necesidades del paciente, las características del caso y las condiciones de uso. Una adecuada evaluación de estos aspectos permitirá optimizar los resultados de la rehabilitación dental.

Abstract

This study aimed to evaluate and compare the mechanical fracture resistance of two different brands of fiberglass posts used in the dental clinic of Santo Tomás University, Floridablanca campus. Fiberglass posts play an important role in the rehabilitation of endodontically treated teeth because they provide support, stability, and proper distribution of occlusal forces, helping to preserve the remaining dental structure and improve the longevity of restorations. An in vitro experimental study was conducted using a sample of 60 maxillary first premolars obtained from the university’s tooth bank. The specimens were divided into three groups: 20 teeth restored with the first brand of fiberglass posts, 20 restored with the second brand, and 20 teeth assigned to the control group. All teeth underwent endodontic treatment followed by the corresponding rehabilitation procedure. Subsequently, the samples were subjected to vertical compressive load tests to determine their fracture resistance and compare the mechanical performance of the different groups. The results demonstrated the behavior of the fiberglass post groups under vertical compressive forces. However, statistical analysis revealed that none of the observed effects were statistically significant. These findings indicate that there is insufficient evidence to conclude that either brand has a significant influence on peak load capacity or fracture resistance when compared with the control group. Therefore, under the conditions of this study, both fiberglass post systems exhibited similar mechanical performance. In conclusion, the two evaluated brands of fiberglass posts showed comparable resistance to vertical compressive forces and fracture. Since no significant differences were found between them, the selection of a specific brand should not be based solely on mechanical resistance. Instead, clinicians should consider other relevant factors, including the patient’s clinical needs, treatment objectives, handling characteristics, availability, and expected conditions of use. Careful assessment of these factors will help dental professionals choose the most appropriate fiberglass post system and achieve optimal outcomes in the rehabilitation of endodontically treated teeth.

Idioma

spa

Palabras clave

Citación

Andrade Flórez, M. A., Sarquez Parra, D. A. (2026) Comparación de dos marcas comerciales de postes de fibra de vidrio realizados sobre premolares examinando la resistencia mecánica a la fractura [Trabajo d epregrado] Universidad Santo Tomás, Bucaramanga, Colombia

Licencia Creative Commons