Utilidad del sistema waterpiñ power flosser en la eliminación de la burbuja apical durante el tratamiento endodóntico
Cargando...
Fecha
2016
Enlace al recurso
DOI
ORCID
Google Scholar
Cvlac
gruplac
Descripción Dominio:
Título de la revista
ISSN de la revista
Título del volumen
Editor
Universidad Santo Tomás
Compartir
Documentos PDF
Cargando...
Resumen
Determinar la utilidad del sistema Waterpik Power Flosser en la eliminación de la burbuja apical, utilizando un método radiográfico con medio de contraste. Metodología: Este es un estudio observacional descriptivo cuasi experimental; A 90 dientes unirradiculares humanos permanentes con formación apical completa, se les realizó apertura cameral, se prepararon con lima Large del sistema Wave One, se irrigaron con Hipoclorito de Sodio, se realizó selle apical con barniz de esmalte, y se dividieron aleatoriamente en dos grupos, cada uno con el 50% de la muestra. El grupo A se activó con el sistema Endoactivator y el grupo B se activó con el sistema Waterpik Power Flosser con la punta del Endoactivator; cada diente fue irrigado con cloruro de cesio y se tomó radiografía para comprobar la presencia de la burbuja apical. En cada grupo la solución fue activada durante 15 segundos y se tomó radiografía periapical; en los que no se disolvió la burbuja, se activó nuevamente durante 30 segundos y en los que no, en un minuto. Resultados: Se formó la burbuja apical en el 100% de la muestra. El grupo Endoactivator disolvió la burbuja apical con más frecuencia (55%), que en el grupo Waterpik Power Flosser (48%), sin encontrarse diferencia estadísticamente significativa. Conclusión: No existe un efecto diferencial entre los dos métodos. Las diferencias entre los sistemas fueron el tipo de movimiento, frecuencia y velocidad, factores que no alteran los resultados obtenidos. Se comprueba la utilidad del sistema Waterpik Power Flosser en disolver la burbuja apical.
Abstract
Objective: Asses the usefulness of the Waterpik Power Flosser system on the removal of the apical vapor lock using a radiographic evaluation with a contrast medium. Methods: This is an observational descriptive experimental study, 120 uniradicular permanent teeth with full root development were used. Coronal access was gained and teeth were prepared with the large instrument of the WaveOne system. They were also irrigated with sodium hypochlorite, the roots were sealed externally with nail polish. Teeth were divided randomly into 2 groups, 60 teeth each. Group A was activated with the Endoactivator system and group B with the Waterpik Power Flosser system. Each tooth was irrigated with a solution containing cesium chloride and an x—ray was taken to check the presence of the apical vapor lock. In each group the solution was activated for 15 seconds and a new x—ray was taken. In those teeth were the vapor lock didn't resolve, the irrigant was activated once more for 30 seconds or a minute. Results: the apical vapor lock was present in all the samples. The Endoactivator group dissolved the vapor lock more frequently (55%) than de waterpik power flosser group (48%) with no statistical difference. Conclusion: There isn't a difference between the two methods. The differences were the type of movement and the speed, factors that in turn didn't modify the results. Then this study confirms the usefulness of the waterpik power flosser in the removal of the apical vapor lock.
Idioma
spa
Palabras clave
Citación
Guevara Rocha, Y. A. Quiñones Cárdenas, L. S. (2016). Utilidad del sistema waterpiñ power flosser en la eliminación de la burbuja apical durante el tratamiento endodóntico. [Trabajo de Especialización]. Universidad Santo Tomás, Bucaramanga, Colombia.
Colecciones
Licencia Creative Commons
Atribución-NoComercial-SinDerivadas 2.5 Colombia