Resistencia a la fractura ante fuerzas compresivas en láminas de G-CAM Grafeno y Vita Enamic. Comparación in vitro
Cargando...
Fecha
2022-01-19
Director
Enlace al recurso
DOI
ORCID
Google Scholar
Cvlac
gruplac
Descripción Dominio:
Título de la revista
ISSN de la revista
Título del volumen
Editor
Universidad Santo Tomás
Compartir
Documentos PDF
Cargando...
Resumen
La pérdida de la estructura dental se debe a diversos factores tales como traumatismos, caries, iatrogenias generando un desgaste de la estructura del diente, siendo solventados con diferentes procedimientos restauradores, razón fundamental por la cual se buscan materiales idóneos para devolver estética y principalmente función. Objetivo Evaluar la resistencia compresiva a la fractura en láminas de G-CAM Grafeno y Vita Enamic. Materiales y métodos Se realizó una prueba in vitro, donde se tuvo más de un grupo de comparación, caracterizado por la intervención en el grupo 0 y en el grupo 1 se utilizaron un total de 40 láminas, 20 para el grupo 0: G-CAM Grafeno y 20 para el grupo 1: Vita Enamic. Se evaluaron variables como son: material, resistencia, tiempo y fractura. Se digitaron los datos en el software Excel ® y analizaron en Stata 14 ® con un análisis descriptivo de las variables, mediante proporciones, medidas de frecuencia, tendencia central y dispersión, finalmente se evaluó la distribución de los datos utilizando la prueba de Shapiro Wilk W. Resultados Mostraron un promedio global de los dos grupos comparados de 1,26[±0,54] Nw (7,53[±3,25] MPa), con un promedio de tiempo global de ocurrencia de la fractura 1,01[±0,49] en Minutos (61,0[±29,9] Seg). Para el G-CAM Grapheno la resistencia máxima a la fractura fue de 1,67[±0,41] Nw (9,95[±2,46] MPa), con un tiempo de ocurrencia de 1,2[±0,53] en Minutos (77,58[±32,37] Seg). Para el Vita Enamic el valor registrado en resistencia máxima a la fractura fue de 0,85[±0,30] Nw (5,11[±1,81] MPa), con un tiempo de ocurrencia de 0,73[±0,24] en Minutos (44,20[±14,47] Seg). Conclusiones La resistencia compresiva a la fractura entre las láminas de G-CAM Grafeno y Vita Enamic, evidenciaron diferencias estadísticamente significativas, siendo superior el G-CAM Grafeno.
Abstract
The loss of dental structure is due to various factors such as trauma, caries, iatrogenesis generating wear of the tooth structure, being solved with different restorative procedures, a fundamental reason why suitable materials are sought to restore aesthetics and mainly function. Objective To evaluate the compressive resistance to fracture in G-CAM Graphene and Vita Enamic sheets. Materials and methods An in vitro test was carried out, where there was more than one comparison group, characterized by the intervention in group 0 and in group 1 a total of 40 slides were used, 20 for group 0: G-CAM Graphene and 20 for group 1: Vita Enamic. Variables such as: material, resistance, time, and fracture were evaluated. The data were entered in the Excel ® software and analyzed in Stata 14 ® with a descriptive analysis of the variables, through proportions, frequency measures, central tendency, and dispersion, finally the distribution of the data was evaluated using the Shapiro Wilk W test. Results They showed a global mean of the two compared groups of 1.26 [± 0.54] Nw (7.53 [± 3.25] MPa), with a mean global time of occurrence of the fracture 1.01 [ ± 0.49] in Minutes (61.0 [± 29.9] Sec). For G-CAM Graphene the maximum resistance to fracture was 1.67 [± 0.41] Nw (9.95 [± 2.46] MPa), with an occurrence time of 1.2 [± 0, 53] in Minutes (77.58 [± 32.37] Sec). For the Vita Enamic, the value recorded in maximum resistance to fracture was 0.85 [± 0.30] Nw (5.11 [± 1.81] MPa), with an occurrence time of 0.73 [± 0, 24] in Minutes (44.20 [± 14.47] Sec). Conclusions The compressive resistance to fracture between the G-CAM Graphene and Vita Enamic sheets showed statistically significant differences, with G-CAM Graphene being superior.
Idioma
spa
Palabras clave
Citación
Landinez Jaimes, T. P., Pineda Castañeda, K. L. y Trujillo Ramírez, P. A. (2022). Resistencia a la fractura ante fuerzas compresivas en láminas de G-CAM Grafeno y Vita Enamic. Comparación in vitro. [Tesis de Posgrado]. Universidad Santo Tomás. Bucaramanga, Colombia.
Colecciones
Licencia Creative Commons
Atribución-CompartirIgual 2.5 Colombia
Atribución 2.5 Colombia
Atribución-CompartirIgual 2.5 Colombia
Atribución 2.5 Colombia
Atribución-CompartirIgual 2.5 Colombia