Resistencia compresiva de dos resinas nanohíbridas en restauraciones estampadas tipo Table Top: estudio experimental in vitro
Cargando...
Fecha
Director
Enlace al recurso
DOI
ORCID
Google Scholar
Cvlac
gruplac
Descripción Dominio:
Título de la revista
ISSN de la revista
Título del volumen
Editor
Universidad Santo Tomás
Compartir
Documentos PDF
Descripción
El presente estudio in vitro de tipo comparativo evaluó la resistencia a fuerzas compresivas de dos resinas nanohíbridas utilizadas en restauraciones estampadas tipo table tops en zona posteroinferior sobre modelos impresos en 3D, a saber, la resina Tetric N-Ceram 2 (Ivoclar Vivadent), con registro INVIMA, y la resina DX Universal (Dentex), sin certificación local, con el objetivo de generar evidencia científica que oriente las decisiones clínicas en el contexto colombiano. Metodológicamente, se fabricaron 40 especímenes, 20 por grupo, mediante técnica de estampado directo tipo table top estandarizada digitalmente en EXOCAD y trabajados en la máquina universal AUTOGRAPH SHIMADZU AG-I a 1 mm/min con punzón de 4 mm de diámetro. En materia de resultados, el análisis estadístico se ejecutó en STATA 14 e incluyó prueba de Shapiro-Wilk, prueba de Levene, t de Welch, Mann-Whitney U y d de Cohen, encontrando que el grupo Tetric N-Ceram 2 presentó una resistencia compresiva media de 161,34 ± 26,00 MPa (CV = 16,1%) y el grupo DX Universal de 177,90 ± 46,79 MPa (CV = 26,3%) y no se detectó diferencia estadísticamente significativa entre grupos (t de Welch: p = 0,1771; Mann-Whitney U: p = 0,4091; d de Cohen = −0,437). La prueba de Levene evidenció varianzas heterogéneas (F = 6,5518; p = 0,0146), reflejando mayor imprevisibilidad mecánica del grupo DX Universal lo que permite concluir que bajo las condiciones experimentales establecidas ambas resinas presentan desempeño compresivo comparable.
Abstract
This comparative in vitro study evaluated the compressive strength of two nanohybrid resins used in table-top stamped restorations in the posterior-inferior region on 3D-printed models: Tetric N-Ceram 2 resin (Ivoclar Vivadent), registered with INVIMA (Colombian National Institute of Food and Drug Surveillance), and DX Universal resin (Dentex), which lacks local certification. The objective was to generate scientific evidence to guide clinical decisions in the Colombian context. Methodologically, 40 specimens were fabricated, 20 per group, using a digitally standardized table-top direct stamping technique in EXOCAD and processed on an AUTOGRAPH SHIMADZU AG-I universal stamping machine at 1 mm/min with a 4 mm diameter punch. Regarding the results, the statistical analysis was performed in STATA 14 and included Shapiro-Wilk test, Levene test, Welch's t, Mann-Whitney U and Cohen's d, finding that the Tetric N-Ceram 2 group presented a mean compressive strength of 161.34 ± 26.00 MPa (CV = 16.1%) and the DX Universal group of 177.90 ± 46.79 MPa (CV = 26.3%) and no statistically significant difference was detected between groups (Welch's t: p = 0.1771; Mann-Whitney U: p = 0.4091; Cohen's d = −0.437). Levene's test revealed heterogeneous variances (F = 6.5518; p = 0.0146), reflecting greater mechanical unpredictability in the DX Universal group. This allows us to conclude that, under the established experimental conditions, both resins exhibit comparable compressive performance.
Idioma
spa
Palabras clave
Citación
Acevedo Vera, S. M. Montenegro Ocampo, L. E. Wilches Vega, S. M. (2026) Resistencia compresiva de dos resinas nanohíbridas en restauraciones estampadas tipo Table Top: estudio experimental in vitro [Tesis de posgrado] Universidad Santo Tomás Bucaramanga, Colombia