Estudio patológico del edificio CAMI (Centro Administrativo Municipal Institucional) del municipio de Tierralta, departamento de Córdoba

Cargando...
Miniatura

Enlace al recurso

DOI

gruplac

Descripción Dominio:

Título de la revista

ISSN de la revista

Título del volumen

Editor

Universidad Santo Tomás

Compartir

Documentos PDF

Descripción

Este estudio patológico se enfoca en realizar un diagnóstico integral del Centro Administrativo Municipal Institucional (CAMI) en Tierralta, Córdoba. El objetivo principal es hallar la raíz de los daños o lesiones actuales en la edificación para medir qué tanto están afectando su integridad. A partir de estos hallazgos, definimos una serie de rutas de intervención preventivas y correctivas, que buscan rescatar la seguridad de la estructura y extender su vida útil. El edificio cuenta con cinco (5) niveles y más de 2.650 m2 construidos, aunque hoy solo se aprovecha una parte; de hecho, tres de sus pisos están prácticamente abandonados. Para este análisis, seguimos el método de la “Historia Clínica del Edificio”, lo que implicó desde revisar planos y licencias antiguas hasta realizar visitas técnicas de inspección visual para clasificar cada daño según su origen (físico, mecánico, químico o biológico). Los resultados del diagnóstico confirman que la durabilidad y el desempeño estructural del CAMI están seriamente comprometidos. Por lo tanto, es urgente iniciar una intervención prioritaria que ataque las causas raíz del daño. Solo un plan integral de rehabilitación técnica, acompañado de un mantenimiento sostenible, permitirá rescatar el edificio.

Abstract

This structural analysis focuses on conducting a comprehensive diagnosis of the Municipal Administrative Center (CAMI) in Tierralta, Córdoba. The main objective is to identify the root causes of the current damage or deterioration in the building to assess the extent to which it is affecting its structural integrity. Based on these findings, we defined a series of preventive and corrective intervention plans aimed at restoring the building's safety and extending its lifespan. The building has five levels and over 2,650 m2 of constructed area, although only a portion is currently in use; in fact, three of its floors are practically abandoned. For this analysis, we followed the "Building History" method, which involved reviewing old plans and permits, as well as conducting technical visual inspections to classify each type of damage according to its origin (physical, mechanical, chemical, or biological). The diagnostic results confirm that the durability and structural performance of the CAMI are seriously compromised. Therefore, it is urgent to initiate a priority intervention that addresses the root causes of the damage. Only a comprehensive technical rehabilitation plan, accompanied by sustainable maintenance, will allow the building to be rescued

Idioma

spa

Palabras clave

Citación

Madera Martínez, L. M. (2026). Estudio patológico del edificio CAMI (centro administrativo municipal institucional) del municipio de Tierralta, departamento de Córdoba. [Especialización. Universidad Santo Tomás]. Repositorio Institucional.

Licencia Creative Commons

Attribution-NonCommercial-NoDerivs 2.5 Colombia