Desarrollo de un Prototipo Analizador de Gases Contaminantes Industriales para la Empresa SIAM INGENIERIA S.A.S.
| dc.contributor.advisor | Monroy Hernández, José Leonardo | |
| dc.contributor.author | González Angarita, José Ignacio | |
| dc.contributor.corporatename | Universidad Santo Tomás | spa |
| dc.contributor.cvlac | https://scienti.minciencias.gov.co/cvlac/visualizador/generarCurriculoCv.do?cod_rh=0001743659 | |
| dc.contributor.cvlac | https://scienti.minciencias.gov.co/cvlac/visualizador/generarCurriculoCv.do?cod_rh=0001446751 | |
| dc.contributor.googlescholar | https://scholar.google.com/citations?hl=es&user=pmrz_ZoAAAAJ | |
| dc.contributor.orcid | https://orcid.org/0000-0003-2284-9673 | |
| dc.date.accessioned | 2023-03-13T14:37:30Z | |
| dc.date.available | 2023-03-13T14:37:30Z | |
| dc.date.issued | 2023-03-10 | |
| dc.description | SIAM INGENIERIA, una empresa especializada en el monitoreo y consultoría de la calidad del aire ha encontrado dificultades en el manejo de los equipos analizadores de gas contaminante asociadas al peso, transporte y gasto de energía. Para solucionar esta necesidad, se presenta una mejora por medio del desarrollo de un prototipo de baja potencia equipado con sensores electroquímicos. Este dispositivo es capaz de tomar muestras en tiempo real de gases contaminantes (CO, NO, SO2 y O3) presentes en el aire, especialmente aquellos con alta emisión en empresas industriales. El proceso de elección de los sensores disponibles en el mercado y el diseño del sistema electrónico y la interfaz de usuario se detallan en este artículo para lograr la fabricación de este analizador. También se realiza el diseño computarizado de la carcasa del dispositivo y se hace una comparación con un analizador de gas certificado en la organización en una simulación de un plan de monitoreo real. Este prototipo tiene como objetivo solucionar los problemas actuales y mejorar la eficiencia en el monitoreo de la calidad del aire. | spa |
| dc.description.abstract | monitoring and consulting, has encountered difficulties in handling pollutant gas analyzer equipment associated with weight, transportation, and energy expenditure. To solve this need, an improvement is presented through the development of a low power prototype equipped with electrochemical sensors. This device can take samples in real time of polluting gases (CO, NO, SO2 and O3) present in the air, especially those with high emissions in industrial companies. The process of choosing the sensors available in the market and the design of the electronic system and the user interface are detailed in this article to achieve the manufacture of this analyzer. The computerized design of the device casing is also performed, and a comparison is made with a certified gas analyzer in the organization in a simulation of a real monitoring plan. This prototype aims to solve current problems and improve efficiency in monitoring air quality. | spa |
| dc.description.degreelevel | Pregrado | spa |
| dc.description.degreename | Ingeniero en Mecatrónica | spa |
| dc.description.domain | https://www.ustabuca.edu.co/ | spa |
| dc.format.mimetype | application/pdf | |
| dc.identifier.citation | González, J. I. (2023). Desarrollo de un Prototipo Analizador de Gases Contaminantes Industriales para la Empresa SIAM INGENIERIA S.A.S. [Trabajo de Grado, Universidad Santo Tomás]. Repositorio Institucional. | spa |
| dc.identifier.instname | instname:Universidad Santo Tomás | spa |
| dc.identifier.reponame | reponame:Repositorio Institucional Universidad Santo Tomás | spa |
| dc.identifier.repourl | repourl:https://repository.usta.edu.co | spa |
| dc.identifier.uri | http://hdl.handle.net/11634/49884 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Santo Tomás | spa |
| dc.publisher.branch | CRAI-USTA Bucaramanga | spa |
| dc.publisher.faculty | Facultad de Ingeniería Mecatrónica | spa |
| dc.publisher.program | Pregrado Ingeniería Mecatrónica | spa |
| dc.relation.references | SIAM Ingeniería, «Misión y Visión,» 2012. [En línea]. Available: https://siamingenieria.com/wpf/about/. | spa |
| dc.relation.references | L. Boissoneault, «The Deadly Donora Smog of 1948 Spurred Environmental Protection—But Have We Forgotten the Lesson?,» Smithsonian, 26 Octubre 2018. | spa |
| dc.relation.references | «The Air Quality Act of 1967,» Journal of the Air Pollution Control Association, pp. 62-71, 1968. | spa |
| dc.relation.references | EPA, «United States Enviromental Protection Agency,» 12 Septiembre 2022. [En línea]. Available: https://www.epa.gov/laws-regulations/summary-clean-air-act. | spa |
| dc.relation.references | IDEAM, «Ideam.gov.co,» Febrero 2008. [En línea]. Available: http://www.ideam.gov.co/documents/51310/527391/Protocolo+para+el+Monitoreo+y+seguimiento+de+la+calidad+del+aire.pdf/6b2f53c8-6a8d-4f3d-b210-011a45f3ee88. | spa |
| dc.relation.references | K. Ishida.Japón Patente 3898462, 1975. | spa |
| dc.relation.references | R. Kinnett, «HACKADAY,» 01 09 2019. [En línea]. Available: https://hackaday.io/project/167435-a-more-complete-air-quality-monitor. | spa |
| dc.relation.references | Thermo Scientific, «Infrared Non-Dispersive CO2 Analyzer Working Principle,» 2015. [En línea]. Available: https://instrumentationtools.com/infrared-non-dispersive-co2-analyzer-working-principle/. | spa |
| dc.relation.references | Thermo Scientific, «Model 49i Instruction Manual UV Photometric O3 Analyzer,» 2011. [En línea]. Available: https://www.thermofisher.com/document-connect/document-connect.html?url=https://assets.thermofisher.com/TFS-Assets%2FEPM%2Fmanuals%2FEPM-manual-Model%2049i.pdf/. | spa |
| dc.relation.references | Thermo Scientific, «Model 42i Instruction Manual Chemiluminescence NOx Analyzer,» 2007. [En línea]. Available: https://www.thermofisher.com/document-connect/document-connect.html?url=https://assets.thermofisher.com/TFS-Assets%2FLSG%2Fmanuals%2FEPM-manual-Model%2042i.pdf. | spa |
| dc.relation.references | Thermo Scientific, «Model 43i Instruction Manual Pulsed Fluorescence SO2 Analyzer,» 2015. [En línea]. Available: https://www.thermofisher.com/document-connect/document-connect.html?url=https://assets.thermofisher.com/TFS-Assets%2FLSG%2Fmanuals%2FEPM-manual-Model%2043i.pdf. | spa |
| dc.relation.references | MEMBRAPOR, «Electrochemical Gas Sensors,» 2020. [En línea]. Available: https://www.membrapor.ch/electrochemical-gas-sensors/. | spa |
| dc.relation.references | Code of Federal Regulations, «Table B-1 to Subpart B of Part 53, Title 40,» 2015. [En línea]. Available: https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-53/subpart-B/appendix-Table%20B-1%20to%20Subpart%20B%20of%20Part%2053. | spa |
| dc.relation.references | SpecSensor, «Digital Gas Sensor Developer Kit: Digital SDK,» 2017. [En línea]. Available: https://www.spec-sensors.com/product/digital-gas-sensor-developer-kit/. | spa |
| dc.relation.references | Ec Sense, «Ozone Gas Module,» 2020. [En línea]. Available: https://ecsense.com/product/tb600b-o3-5-air-quality-sensor-module/. | spa |
| dc.relation.references | J. P. y. J. Pinzón, «Estándares Para Cloud Computing: Estado Del Arte Y Análisis De Protocolos Para Varias Nubes,» Research Gate, Bucaramanga, 2015. | spa |
| dc.relation.references | MathWorks, «MathWorks,» 2022. [En línea]. Available: https://la.mathworks.com/help/matlab/ref/polyfit.html. | spa |
| dc.relation.references | IDEAM, «Instituto de Hidrología, Meteorología y Estudios Ambientales,» 1 Noviembre 2017. [En línea]. Available: http://www.ideam.gov.co/documents/51310/527391/2.+Resoluci%C3%B3n+2254+de+2017+-+Niveles+Calidad+del+Aire..pdf/c22a285e-058e-42b6-aa88-2745fafad39f. [Último acceso: 02 02 2023]. | spa |
| dc.relation.references | I. Amaya, Á. Martínez y A. Rizzo. [En línea]. | spa |
| dc.rights | Atribución-NoComercial-SinDerivadas 2.5 Colombia | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | spa |
| dc.rights.local | Abierto (Texto Completo) | spa |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/2.5/co/ | |
| dc.subject.keyword | Air quality | spa |
| dc.subject.keyword | Gas analyzer | spa |
| dc.subject.keyword | Development | spa |
| dc.subject.keyword | Electrochemical sensors | spa |
| dc.subject.keyword | IoT | spa |
| dc.subject.lemb | tratamiento de gases | spa |
| dc.subject.lemb | Calidad del aire | spa |
| dc.subject.lemb | Depuración de gases | spa |
| dc.subject.proposal | Calidad de aire | spa |
| dc.subject.proposal | Desarrollo | spa |
| dc.subject.proposal | Sensores electroquímicos | spa |
| dc.subject.proposal | IoT | spa |
| dc.subject.proposal | Analizador de gas | spa |
| dc.title | Desarrollo de un Prototipo Analizador de Gases Contaminantes Industriales para la Empresa SIAM INGENIERIA S.A.S. | spa |
| dc.type | bachelor thesis | |
| dc.type.category | Formación de Recurso Humano para la Ctel: Trabajo de grado de Pregrado | spa |
| dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.coarversion | http://purl.org/coar/version/c_ab4af688f83e57aa | |
| dc.type.drive | info:eu-repo/semantics/bachelorThesis | |
| dc.type.local | Tesis de pregrado | spa |
| dc.type.version | info:eu-repo/semantics/acceptedVersion |
Archivos
Bloque original
1 - 4 de 4
Cargando...
- Nombre:
- 2023gonzalezjose
- Tamaño:
- 1.51 MB
- Formato:
- Adobe Portable Document Format
- Descripción:
Cargando...
- Nombre:
- 2023gonzalezjose1
- Tamaño:
- 115.38 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
Cargando...
- Nombre:
- 2023cartaderechosautor
- Tamaño:
- 103.53 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
Cargando...
- Nombre:
- 2023cartaaprobaciónfacultad
- Tamaño:
- 167.82 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
Bloque de licencias
1 - 1 de 1
Cargando...
- Nombre:
- license.txt
- Tamaño:
- 807 B
- Formato:
- Item-specific license agreed upon to submission
- Descripción: