Controlling the variability of air-pulses to determine the thresholds of laryngeal-pharyngeal reflexes using a novel device

dc.contributor.authorGiraldo, Luis F.
dc.contributor.authorAgudelo, Mauricio
dc.contributor.authorArbulu, Mario
dc.contributor.authorOrtiz, Felipe
dc.contributor.authorBurguete, Javier
dc.contributor.authorFernández, Secundino
dc.coverage.campusCRAI-USTA Bogotáspa
dc.date.accessioned2020-01-22T17:20:37Z
dc.date.available2020-01-22T17:20:37Z
dc.date.issued2014-01-09
dc.description.abstractFactors determining the variability of air-pulse pressure to determine the thresholds of laryngealpharyngeal reflexes, which are related to swallowing and airway protection, were explored. Potential factors affecting the reproducibility of air-pulses were experimentally evaluated and included in a multiple linear regression model. A novel device controlling these factors and minimizing variability was designed. Its reproducibility was assessed by the coefficient of variation (CV) of the pressures and duration of air-pulses, and its validity was assessed by comparing obtained pressures and durations with desired pressures and durations. Differences in the pressures of airpulse categories were assessed by a one-way ANOVA of repeated measures, a Tukey test and a box and whisker plot. The distance and angle between the exit of the tube conducting the pulses and the surface to be impacted, the diameter of the tube, the feeding pressure of the system, and the duration of air-pulses significantly affected the accuracy of air-pulses. The novel device incorporated electronic valves and a telemeter for use during the fiberoptic endoscopic evaluation of swallowing. The differences between the desired and obtained pressures and durations were below 3%. The CV of the air-pulse pressures of the novel device was 0.02. The CV of air-pulse duration was 0.05. The oneway ANOVA, Tukey test and box and whisker plot showed that the outlet pressures of air-pulse categories had statistically significant differences between them without overlap between categories, which helps to obtain an accurate threshold.spa
dc.description.domainhttp://unidadinvestigacion.usta.edu.cospa
dc.format.mimetypeapplication/pdfspa
dc.identifier.doihttps://doi.org/10.1109/BIBE.2013.6701652spa
dc.identifier.urihttp://hdl.handle.net/11634/21010
dc.relation.referencesJ. E. Aviv, J. H. Martin, T. Kim, R. L. Sacco, J. E. Thomson, B. Diamond, et al., "Laryngopharyngeal sensory discrimination testing and the laryngeal adductor reflex," Ann Otol Rhinol Laryngol, vol. 108, pp. 725-30, Aug 1999.spa
dc.relation.referencesJ. E. Aviv, J. H. Martin, M. S. Keen, M. Debell, and A. Blitzer, "Air pulse quantification of supraglottic and pharyngeal sensation: A new technique," Annals of Otology, Rhinology and Laryngology, vol. 102, pp. 777-780, 1993.spa
dc.relation.referencesJ. J. Cunningham, S. L. Halum, S. G. Butler, and G. N. Postma, "Intraobserver and interobserver reliability in laryngopharyngeal sensory discrimination thresholds: a pilot study," Ann Otol Rhinol Laryngol, vol. 116, pp. 582-8, Aug 2007.spa
dc.relation.referencesJ. E. Aviv, R. L. Sacco, J. Thomson, R. Tandon, B. Diamond, J. H. Martin, et al., "Silent laryngopharyngeal sensory deficits after stroke," Ann Otol Rhinol Laryngol, vol. 106, pp. 87-93, Feb 1997.spa
dc.relation.referencesJ. E. Aviv, J. Spitzer, M. Cohen, G. Ma, P. Belafsky, and L. G. Close, "Laryngeal adductor reflex and pharyngeal squeeze as predictors of laryngeal penetration and aspiration," Laryngoscope, vol. 112, pp. 338-41, Feb 2002.spa
dc.relation.referencesP. K. Ku, A. C. Vlantis, S. F. Leung, K. Y. Lee, D. M. Cheung, V. J. Abdullah, et al., "Laryngopharyngeal sensory deficits and impaired pharyngeal motor function predict aspiration in patients irradiated for nasopharyngeal carcinoma," Laryngoscope, vol. 120, pp. 223-8, Feb 2010.spa
dc.relation.referencesP. W. Perlman, M. A. Cohen, M. Setzen, P. C. Belafsky, J. Guss, K. F. Mattucci, et al., "The risk of aspiration of pureed food as determined by flexible endoscopic evaluation of swallowing with sensory testing," Otolaryngology - Head and Neck Surgery, vol. 130, pp. 80-83, 2004.spa
dc.relation.referencesJ. E. Aviv, R. L. Sacco, J. P. Mohr, J. L. Thompson, B. Levin, S. Sunshine, et al., "Laryngopharyngeal sensory testing with modified barium swallow as predictors of aspiration pneumonia after stroke," Laryngoscope, vol. 107, pp. 1254-60, Sep 1997.spa
dc.relation.referencesJ. E. Aviv, "Sensory discrimination in the larynx and hypopharynx," Otolaryngology - Head and Neck Surgery, vol. 116, pp. 331-334, 1997.spa
dc.relation.referencesM. J. Hammer, "Design of a new somatosensory stimulus delivery device for measuring laryngeal mechanosensory detection thresholds in humans," IEEE Transactions on Biomedical Engineering, vol. 56, pp. 1154-1159, April 2009.spa
dc.relation.referencesP. R. Kearney, C. J. Poletto, E. A. Mann, and C. L. Ludlow, "Suppression of thyroarytenoid muscle responses during repeated air pressure stimulation of the laryngeal mucosa in awake humans," Ann Otol Rhinol Laryngol, vol. 114, pp. 264-70, Apr 2005.spa
dc.relation.referencesJ. M. Bland and D. G. Altman, "Statistics Notes: Measurement error proportional to the mean," BMJ, vol. 313, p. 106, July 13, 1996 1996.spa
dc.rightsAtribución-NoComercial-CompartirIgual 2.5 Colombia*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/2.5/co/*
dc.subject.keywordAir-pulsespa
dc.subject.keywordNovel devicespa
dc.subject.keywordLaryngealspa
dc.subject.keywordPharyngealspa
dc.titleControlling the variability of air-pulses to determine the thresholds of laryngeal-pharyngeal reflexes using a novel devicespa
dc.type.categoryGeneración de Nuevo Conocimiento: Artículos publicados en revistas especializadas - Electrónicosspa

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Controlling the variability of air-pulses to determine the thresholds of laryngeal-pharyngeal reflexes using a novel device.pdf
Tamaño:
786.13 KB
Formato:
Adobe Portable Document Format
Descripción:
Artículo SCOPUS

Bloque de licencias

Mostrando 1 - 1 de 1
Thumbnail USTA
Nombre:
license.txt
Tamaño:
807 B
Formato:
Item-specific license agreed upon to submission
Descripción: