Estudio patológico en el sótano y semisótano del centro comercial Unicentro Villavicencio (Avenida 40 Villavicencio – Meta-1)
| dc.contributor.advisor | Zambrano Vásquez, Diana Mylena | |
| dc.contributor.author | Capera Hernández, Miguel Andrés | |
| dc.contributor.author | Rodríguez Moreno, Andersson Edward | |
| dc.contributor.corporatename | Universidad Santo Tomás | |
| dc.contributor.cvlac | https://scienti.minciencias.gov.co/cvlac/visualizador/generarCurriculoCv.do?cod_rh=0000116359 | |
| dc.contributor.cvlac | https://scienti.minciencias.gov.co/cvlac/visualizador/generarCurriculoCv.do?cod_rh=0001913908 | |
| dc.contributor.orcid | https://orcid.org/0009-0004-6042-1250 | |
| dc.contributor.orcid | https://orcid.org/0009-0004-9833-6051 | |
| dc.date.accessioned | 2026-06-16T21:43:01Z | |
| dc.date.available | 2026-06-16T21:43:01Z | |
| dc.date.issued | 2026-06-16 | |
| dc.description | El presente trabajo de investigación, desarrollado en el marco de la Maestría en Patología de la Construcción de la Universidad Santo Tomás, tuvo como objetivo realizar un diagnóstico patológico integral de los niveles de sótano y semisótano del Centro Comercial Unicentro Villavicencio, edificación de concreto reforzado inaugurada en 2007, localizada sobre la Avenida 40 de la ciudad de Villavicencio, departamento del Meta. La metodología adoptó un enfoque aplicado-diagnóstico con alcance descriptivo-analítico, bajo la modalidad de caso de estudio. Se ejecutaron cuatro fases secuenciales: revisión documental, inspección visual sistemática mediante fichas de identificación de lesiones con registro fotográfico, aplicación de ensayos no destructivos de esclerometría en seis elementos estructurales representativos, y análisis de información geotécnica del emplazamiento. Se identificaron y clasificaron nueve patrones de deterioro, distribuidos en las siguientes categorías según su origen: físico (44,4 %), mecánico (22,2 %), químico (11,1 %), biológico (11,1 %) y antropológico (11,1 %). Las manifestaciones predominantes correspondieron a humedades por filtración en placas de entrepiso y muros de contención, fisuración superficial, eflorescencias por migración de sales, biodeterioro en zonas de baja ventilación y signos incipientes de corrosión en elementos metálicos expuestos. Según su nivel de severidad, el 44,4 % de las lesiones se clasificó como leve, el 44,4 % como moderada y el 11,2 % como alta. Los ensayos de esclerometría arrojaron valores de resistencia superficial del concreto entre 12,25 MPa y 23,04 MPa, con un promedio de 18,75 MPa, indicando conservación general de la capacidad funcional del material, aunque con deterioro superficial diferencial en zonas de humedad permanente. El análisis geotécnico evidenció que la edificación se asienta sobre un suelo tipo D, con influencia directa del caño Maizaro y precipitaciones anuales superiores a los 4.383 mm, condiciones que explican la recurrencia y distribución espacial de los patrones de deterioro identificados. A partir del diagnóstico, se formuló una propuesta de intervención de carácter preventivo-correctivo y un plan de mantenimiento estructurado. Se concluye que la edificación conserva condiciones generales de estabilidad estructural y funcionalidad; no obstante, la persistencia de lesiones de severidad moderada asociadas a humedad representa un riesgo para su durabilidad a mediano y largo plazo en ausencia de intervención oportuna. | |
| dc.description.abstract | The present research work, developed within the framework of the Master's in Construction Pathology at the Universidad Santo Tomás, aimed to conduct a comprehensive pathological diagnosis of the basement and semi-basement levels of the Unicentro Villavicencio Shopping Center, a reinforced concrete building inaugurated in 2007, located on Avenida 40 in the city of Villavicencio, department of Meta. The methodology adopted an applied-diagnostic approach with a descriptive-analytical scope, under the case study modality. Four sequential phases were executed: document review, systematic visual inspection using injury identification sheets with photographic records, application of non-destructive Schmidt hammer tests on six representative structural elements, and analysis of geotechnical information of the site. Nine patterns of deterioration were identified and classified, distributed into the following categories according to their origin: physical (44.4%), mechanical (22.2%), chemical (11.1%), biological (11.1%), and anthropological (11.1%). The predominant manifestations corresponded to moisture from filtration in floor slabs and retaining walls, superficial cracking, efflorescence from salt migration, biodeterioration in areas with low ventilation, and early signs of corrosion in exposed metal elements. According to their level of severity, 44.4% of the lesions were classified as mild, 44.4% as moderate, and 11.2% as severe. The sclerometry tests yielded surface resistance values of the concrete between 12.25 MPa and 23.04 MPa, with an average of 18.75 MPa, indicating a general preservation of the material's functional capacity, although with differential superficial deterioration in areas of permanent moisture. The geotechnical analysis revealed that the building is situated on a type D soil, with direct influence from the Maizaro stream and annual rainfall exceeding 4,383 mm, conditions that explain the recurrence and spatial distribution of the identified deterioration patterns. Based on the diagnosis, a preventive-corrective intervention proposal and a structured maintenance plan were formulated. It is concluded that the building maintains general conditions of structural stability and functionality; however, the persistence of moderate severity damage associated with moisture poses a risk to its medium and long-term durability in the absence of timely intervention. | |
| dc.description.degreelevel | Maestría | spa |
| dc.description.degreename | Magister en Patología de la Construcción | spa |
| dc.format.mimetype | application/pdf | |
| dc.identifier.citation | Rodríguez Moreno, A. E. y Capera Hernandez , M (2026). Estudio patológico en el sótano y semisótano del centro comercial Unicentro Villavicencio (Avenida 40 Villavicencio – Meta-1) [Trabajo de Maestría, Universidad Santo Tomás]. Repositorio Institucional | |
| dc.identifier.instname | instname:Universidad Santo Tomás | spa |
| dc.identifier.reponame | reponame:Repositorio Institucional Universidad Santo Tomás | spa |
| dc.identifier.repourl | repourl:https://repository.usta.edu.co | spa |
| dc.identifier.uri | http://hdl.handle.net/11634/72686 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Santo Tomás | spa |
| dc.publisher.branch | CRAI-USTA Bogotá | |
| dc.publisher.faculty | Facultad de Ingeniería Civil | spa |
| dc.publisher.program | Maestría en Patología de la Construcción | spa |
| dc.relation.references | American Concrete Institute. (2001). Control of cracking in concrete structures (ACI 224R-01). ACI Committee 224. | |
| dc.relation.references | American Concrete Institute. (2014). Guide for inspection and maintenance of concrete structures (ACI 357R-14). ACI Committee 357 | |
| dc.relation.references | American Concrete Institute. (2015). Guide to the use of waterproofing, dampproofing, protective, and decorative barrier systems for concrete (ACI 515.2R-13). ACI Committee 515. | |
| dc.relation.references | American Concrete Institute. (2016). Code requirements for assessment, repair, and rehabilitation of existing concrete structures (ACI 562-16) and commentary. ACI Committee 562. | |
| dc.relation.references | American Concrete Institute. (2019). Building code requirements for structural concrete (ACI 318-19) and commentary (ACI 318R-19). ACI Committee 318. | |
| dc.relation.references | American Concrete Institute. (2020). Guide to concrete repair (ACI 546R-20). ACI Committee 546. | |
| dc.relation.references | ASTM International. (2013). Standard test method for obtaining and testing drilled cores and sawed beams of concrete (ASTM C42/C42M-13). ASTM International | |
| dc.relation.references | ASTM International. (2013). Standard test method for rebound number of hardened concrete (ASTM C805/C805M-13). ASTM International. | |
| dc.relation.references | Broto, C. (2005). Enciclopedia de patologías de la construcción (Vols. 1–4). Structure. | |
| dc.relation.references | Cabrera, J., & García, M. (2017). Patologías en estructuras de concreto. Editorial Universitaria | |
| dc.relation.references | Castro, J. L. (2012). Modelos estadísticos para la predicción del deterioro en estructuras de concreto armado. Revista Ingeniería y Ciencia, 8(15), 45–62. | |
| dc.relation.references | García, L. R. (2021). Deterioro en estructuras urbanas de Villavicencio: Análisis y estrategias de intervención. Revista Colombiana de Ingeniería, 19(2), 33–47. | |
| dc.relation.references | Hassan, M., & Al-Nasra, M. (2020). Morphological patterns of cracks in concrete structures. Journal of Structural Integrity, 12(3), 211–224. | |
| dc.relation.references | Huang, Y., Zhang, T., & Li, Y. (2015). Electrochemical corrosion of steel reinforcement in concrete. Corrosion Science, 98, 555–567 | |
| dc.relation.references | Instituto de Hidrología, Meteorología y Estudios Ambientales. (2023). Caracterización climatológica del municipio de Villavicencio, departamento del Meta. IDEAM. | |
| dc.relation.references | International Organization for Standardization. (2007). Preparation of steel substrates before application of paints and related products — Visual assessment of surface cleanliness — Part 1 (ISO 8501-1:2007). ISO. | |
| dc.relation.references | Katz, S. (2017). Corrosion of reinforced concrete in marine environments: A case study from Miami, Florida. Journal of Structural Engineering, 143(4), 04016228 | |
| dc.relation.references | López, M. P. (2015). Modelos de corrosión en armaduras de acero en estructuras de concreto. Revista de Ingeniería Estructural, 21(1), 55–70. | |
| dc.relation.references | López, R. G. (2018). Microorganisms and biodeterioration in construction materials. Materials and Microbiology, 7(2), 101–118 | |
| dc.relation.references | Matos, R., & Silva, A. (2020). Environmental factors affecting the durability of concrete. Construction and Building Materials, 253, Artículo 119164. https://doi.org/10.1016/j.conbuildmat.2020.119164 | |
| dc.relation.references | Ministerio de Vivienda, Ciudad y Territorio. (2010). Reglamento colombiano de construcción sismo resistente NSR-10. Gobierno de Colombia. | |
| dc.relation.references | Neville, A. M. (2012). Properties of concrete (5.a ed.). Pearson Education | |
| dc.relation.references | Vanderghem, C., Jacobs, F., & Vanherpe, R. (2013). Saline efflorescence formation in porous materials. Construction and Building Materials, 45, 145–153. | |
| dc.relation.references | Yin, R. K. (2018). Case study research and applications: Design and methods (6.a ed.). SAGE Publications. | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | spa |
| dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.local | Abierto (Texto Completo) | spa |
| dc.subject.keyword | construction pathology | |
| dc.subject.keyword | deterioration in reinforced concrete structures | |
| dc.subject.keyword | moisture due to infiltration | |
| dc.subject.keyword | pathological diagnosis | |
| dc.subject.keyword | non-destructive testing | |
| dc.subject.keyword | underground structures | |
| dc.subject.keyword | humid tropical climate | |
| dc.subject.keyword | corrective and preventive maintenance | |
| dc.subject.lemb | Patologia de la construcicón | |
| dc.subject.lemb | Humedad en edificaciones | |
| dc.subject.lemb | Corrosión de estructuras | |
| dc.subject.proposal | patología de la construcción | |
| dc.subject.proposal | deterioro en estructuras de concreto armado | |
| dc.subject.proposal | humedad por filtración | |
| dc.subject.proposal | diagnóstico patológico | |
| dc.subject.proposal | ensayos no destructivos | |
| dc.subject.proposal | estructuras subterráneas | |
| dc.subject.proposal | clima tropical húmedo | |
| dc.subject.proposal | mantenimiento correctivo y preventivo | |
| dc.title | Estudio patológico en el sótano y semisótano del centro comercial Unicentro Villavicencio (Avenida 40 Villavicencio – Meta-1) | |
| dc.type | master thesis | |
| dc.type.coar | http://purl.org/coar/resource_type/c_bdcc | |
| dc.type.coarversion | http://purl.org/coar/version/c_ab4af688f83e57aa | spa |
| dc.type.drive | info:eu-repo/semantics/masterThesis | spa |
| dc.type.local | Tesis de maestría | spa |
| dc.type.version | info:eu-repo/semantics/acceptedVersion | spa |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- 2026AnderssonRodriguezMiguelCapera.pdf
- Tamaño:
- 12.53 MB
- Formato:
- Adobe Portable Document Format
Bloque de licencias
1 - 3 de 3
Cargando...
- Nombre:
- license.txt
- Tamaño:
- 807 B
- Formato:
- Item-specific license agreed upon to submission
- Descripción:
Cargando...
- Nombre:
- 2026cartadefacultad.pdf
- Tamaño:
- 339.78 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Carta de facultad
Cargando...
- Nombre:
- 2026cartaderechosdeautor.pdf
- Tamaño:
- 318.63 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Carta derechos de autor